Communication, video & sound cables / Dropwire
     
  General information
  Low voltage power cables
  Medium voltage power cables
  Industrial & automotive use
  Control & instrumentation cables
  Comunication, video & sound Cables
  Submarine cable
 
  UTP COMMUNICATION CABLE FOR LIMITED USE, TYPE CM
 
These specifications cover communication cables having soft annealed copper conductor, semirigid PVC insulation and PVC jacket, both flame retardant.

Standars: NEC ARTICLE 800 CSA C22.2

  APPLICATION
 
Communication cables for dwellings use (except plenums and risers) 60°C 300 V.

 

Download Document:

 
  Data of Cable  


(24 AWG, SOLID CONDUCTOR, TWISTED PAIRS)

Typical Electrical Parameters

Mutual Capacitance: 18 pF/ft, 59  pF/m
Char Impedance: 100+/-5W
Attenuation:
Pair – Pair next:
7.8   dB/1000 ft, 2.6   dB/100 m @ 1   MHz
41 dB/1000 ft, 13.5 dB/100 m  @ 1   MHz
17.0 dB/1000 ft, 5.6   dB/100 m @ 4   MHz
28 dB/1000 ft, 9.2   dB/100 m  @ 4   MHz
30.0 dB/1000 ft, 9.9   dB/100 m @ 10 MHz
26 dB/1000 ft, 8.6   dB/100 m  @ 10 MHz
40.0 dB/1000 ft, 13.2 dB/100 m @ 16 MHz
23 dB/1000 ft, 7.6   dB/100 m  @ 16 MHz

 

Size
N° of Pairs
Insulation Thickness
Jacket Thickness
Outside Diameter
Weight
Inches
mm
Inches
mm
IncheS
mm
Ibs./Kft.
Kg/km
2x2x24
2
0.007
0.17
0.013
0.33
0.12
3.0
8.5
12.7
3x2x24
3
0.007
0.17
0.013
0.33
0.12
3.8
12.9
19.2
4x2x24
4
0.007
0.17
0.013
0.51
0.12
4.8
18.6
27.2

22 AWG, SOLID CONDUCTOR, TWISTED PAIRS)

Typical Electrical Parameters

Mutual Capacitance: 18 pF/ft, 59  pF/m

Char Impedance: 100+/-5W

Attenuation: 8.0 dB/1000 ft, 2.7  dB/100 m @ 1 MHz

 

Size
N° of           Pairs
Insulation  Thickness
Jacket   Thickness
Outside  Diameter
Weight
Inches
mm
Inches
mm
Inches
mm
Ibs./Kft.
Kg/km
2x2x22
2
0.008
0.20
0.015
0.38
0.16
4.10
14.60
21.80

 

The provided data are approximated and subject to changes without previous warning


  HOME THE COMPANY PRODUCTS TECHNICAL INFORMATION CONTACT US REPRESENTATIVES
2005 © Electroconductores, C.A. All rights reserved.