Medium voltage power cable / XLPE
     
  General information
  Low voltage power cables
  Medium voltage power cables
  Industrial & automotive use
  Control & instrumentation cables
  Comunication, video & sound Cables
  Submarine cable
 
  Single Conductor XLPE 15 kV 133% I.L.
  Underground primary transmition circuits. May be used in wet or dry locations, installed in duct or direct burial.

Standars: AEIC CS8-00 - ICEA S-97-682-2000
NEMA WC -74 / ICEA S-93-639 - UL 1072

  Electrical Data
 

 

 

 

Continuous operating temperature

 

90º C

Maximum Operating voltage

 

15000 V

Test voltage 1000 kcmil:

 

44 kV ac x 5min

Partial discharge at test voltage

 

< 5 pC



 

 

 

Download Document:

 
  Data of Cable  


 

Conductor
Size
(AWG / MCM)
Stranded Conductor
Thickness
(mils)
Aprox. weight
(Pounds/kft)
Overall Diam. (inch)
Ampacities
Section (MCM)
Number of Wires
Diameter (inch)
Direct. Burial
In Duct
In Air
Wires
Strand
Insulat.
Jacket
Cu
Al
Cu
Al
Cu
Al
Cu
Al
2
66
7
0.097
0.292
175
80
528
385
0.945
222
173
172
135
225
176
2
66
19
0.059
0.287
175
80
523
381
0.939
222
173
172
135
225
176
1
84
19
0.067
0.323
175
80
597
416
0.974
253
197
196
153
259
202
1/0
106
19
0.074
0.362
175
80
684
458
1.014
285
224
222
175
297
234
2/0
133
19
0.084
0.407
175
80
797
510
1.059
323
254
251
198
341
269
3/0
168
19
0.094
0.457
175
80
931
570
1.108
365
289
285
226
391
309
4/0
212
19
0.106
0.512
175
80
1096
641
1.163
412
328
323
257
449
356
250
250
37
0.082
0.559
175
80
1245
707
1.211
451
359
354
283
499
396
300
300
37
0.090
0.612
175
80
1448
802
1.280
495
396
390
313
556
443
350
350
37
0.097
0.661
175
80
1630
878
1.329
536
430
423
341
609
487
500
500
37
0.116
0.789
175
80
2171
1098
1.457
641
520
510
415
751
607
750
750
61
0.111
0.970
175
80
3070
1454
1.638
771
637
625
518
938
770
1000
1000
61
0.128
1.118
175
110
4049
1902
1.878
878
737
718
604
1101
918
1250
1250
91
0.117
1.252
220
110
5060
2368
2.102
923
824
756
675
1157
1025
1500
1500
91
0.128
1.370
220
110
5921
2699
2.220
952
878
780
719
1193
1093

 

Options :

  1. External cover of PVC
  2. “Sun light Resistant” - “Cable Tray Use”
  3. Screen of Concentric Wires

The provided values are approximated and subject to changes without previous warning.

 