Single Conductor EPR 5 kV 100% I.L. |
 |
| |
Underground primary transmition circuits. May be used in wet or dry locations, installed in duct or direct burial. |
|
 |
Standars: AEIC CS8-00 - ICEA S-97-682-2000
NEMA WC -74 / ICEA S-93-639
|
|
 |
| |
Electrical Data |
 |
| |
|
|
|
Continuous operating temperature |
|
90º C |
Maximum Operating voltage |
|
5000 V |
Test voltage |
|
18 kV ac x 5min |
Partial discharge at test voltage |
|
< 5 pC |
|
|
|
Download Document:
|
| |
|
| |
Data of Cable |
|
 |
|
Conductor
Size
(AWG / MCM) |
Stranded Conductor |
Thickness
(mils) |
Aprox. weight
(Pounds/kft) |
Overall Diam. (inch) |
Ampacities |
Section (MCM) |
Number of Wires |
Diameter (inch) |
Direct. Burial |
In Duct |
In Air |
Wires |
Strand |
Insulat. |
Jacket |
Cu |
Al |
Cu |
Al |
Cu |
Al |
Cu |
Al |
8 |
17 |
7 |
0.049 |
0.146 |
90 |
60 |
201 |
166 |
0.589 |
109 |
85 |
78 |
61 |
97 |
76 |
6 |
26 |
7 |
0.061 |
0.183 |
90 |
60 |
247 |
191 |
0.626 |
139 |
108 |
101 |
78 |
128 |
99 |
4 |
42 |
7 |
0.077 |
0.231 |
90 |
60 |
317 |
227 |
0.675 |
179 |
140 |
130 |
101 |
168 |
173 |
2 |
66 |
7 |
0.097 |
0.292 |
90 |
60 |
420 |
278 |
0.736 |
230 |
180 |
168 |
131 |
221 |
173 |
2 |
66 |
19 |
0.059 |
0.287 |
90 |
60 |
416 |
274 |
0.730 |
230 |
180 |
168 |
131 |
221 |
173 |
1 |
84 |
19 |
0.067 |
0.323 |
90 |
60 |
487 |
306 |
0.766 |
276 |
205 |
193 |
150 |
265 |
200 |
1/0 |
106 |
19 |
0.074 |
0.362 |
90 |
60 |
570 |
344 |
0.805 |
297 |
233 |
218 |
171 |
296 |
232 |
2/0 |
133 |
19 |
0.084 |
0.407 |
90 |
80 |
700 |
413 |
0.890 |
337 |
264 |
248 |
195 |
341 |
267 |
3/0 |
168 |
19 |
0.094 |
0.457 |
90 |
80 |
831 |
469 |
0.939 |
377 |
296 |
283 |
222 |
390 |
306 |
4/0 |
212 |
19 |
0.106 |
0.512 |
90 |
80 |
992 |
538 |
0.994 |
426 |
336 |
312 |
253 |
450 |
354 |
250 |
250 |
37 |
0.082 |
0.559 |
90 |
80 |
1138 |
599 |
1.041 |
457 |
365 |
346 |
277 |
492 |
393 |
300 |
300 |
37 |
0.090 |
0.612 |
90 |
80 |
1320 |
674 |
1.094 |
501 |
403 |
381 |
307 |
548 |
440 |
350 |
350 |
37 |
0.097 |
0.661 |
90 |
80 |
1498 |
746 |
1.144 |
541 |
437 |
414 |
335 |
601 |
485 |
500 |
500 |
37 |
0.116 |
0.789 |
90 |
80 |
2045 |
952 |
1.287 |
645 |
527 |
499 |
408 |
743 |
605 |
750 |
750 |
61 |
0.111 |
0.970 |
90 |
80 |
2932 |
1315 |
1.469 |
782 |
650 |
615 |
512 |
945 |
782 |
1000 |
1000 |
61 |
0.128 |
1.118 |
90 |
80 |
3804 |
1657 |
1.632 |
888 |
751 |
706 |
598 |
1109 |
933 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Options : |
- External cover of PVC
- “Sun light Resistant” - “Cable Tray Use”
- Screen of Concentric Wires
|