  Single Conductor EPR 15 kV 133% I.L.
  Underground primary transmition circuits. May be used in wet or dry locations, installed in duct or direct burial.

Standars: AEIC CS8-00 - ICEA S-97-682-2000
NEMA WC -74 / ICEA S-93-639

  Electrical Data
 

 

 

 

Continuous operating temperature

 

90º C

Maximum Operating voltage

 

15000 V

Test voltage 1000 kcmil:

 

44 kV ac x 5min

Partial discharge at test voltage

 

< 5 pC



 

 

Download Document:

 
  Data of Cable  


 

Conduct
Size
(AWG / MCM)

Stranded Conductor

Thickness
(mils)

Aprox. weight
(Pounds/kft)

Overall Diam. (inch)

Ampacities

Section (MCM)

Number of Wires

Diameter (inch)

Direct. Burial

In Duct

In Air

Wires

Strand

Insulat.

Jacket

Cu

Al

Cu

Al

Cu

Al

Cu

Al

2

66

7

0.097

0.292

220

80

640

497

1.035

220

171

170

134

223

174

2

66

19

0.059

0.287

220

80

635

492

1.030

226

175

172

135

225

176

1

84

19

0.067

0.323

220

80

713

533

1.065

248

195

196

154

258

202

1/0

106

19

0.074

0.362

220

80

806

580

1.104

282

222

223

175

297

233

2/0

133

19

0.084

0.407

220

80

925

638

1.150

320

252

253

199

341

268

3/0

168

19

0.094

0.457

220

80

1066

705

1.199

362

286

286

227

391

308

4/0

212

19

0.106

0.512

220

80

1256

802

1.270

409

325

325

258

449

355

250

250

37

0.082

0.559

220

80

1412

873

1.317

448

356

356

284

498

395

300

300

37

0.090

0.612

220

80

1606

960

1.370

492

393

392

314

555

441

350

350

37

0.097

0.661

220

80

1796

1044

1.419

533

427

426

342

608

485

500

500

37

0.116

0.789

220

80

2354

1282

1.547

637

516

513

416

749

604

750

750

61

0.111

0.970

220

110

3348

1731

1.789

769

633

629

519

937

767

1000

1000

61

0.128

1.118

220

110

4286

2140

1.969

876

733

722

606

1099

913

1250

1250

91

0.117

1.252

220

110

5192

2499

2.102

920

822

754

672

1155

1022

1500

1500

91

0.128

1.370

220

110

6063

2841

2.220

949

875

777

717

1190

1090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options :

  1. External cover of PVC
  2. “Sun light Resistant” - “Cable Tray Use”
  3. Screen of Concentric Wires

The provided values are approximated and subject to changes without previous warning.

 